• Users Online: 799
  • Print this page
  • Email this page
RESEARCH ARTICLE
Year : 2017  |  Volume : 4  |  Issue : 1  |  Page : 82-101

Determination of hyperglycaemia-induced epc dysfunction using a panel of cellular assays: Validation of experimental murine and human model systems


Stem Cell Lab, National Centre for Cell Science, Ganeshkhind, Pune – 411007, India

Correspondence Address:
Vaijayanti Kale
Stem Cell Lab, National Centre for Cell Science, Ganeshkhind, Pune – 411007
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2349-3666.240594

Rights and Permissions

Although human and murine Endothelial Progenitor Cells (EPCs) are routinely used for research, the results can only be imperfectly analyzed due to our limited understanding of source-specific differential responses to stress. Although the routinely used cellular and functional assays are effective for detection of EPC dysfunction (EPD) in single source test systems, there is lack of a universal detection system capable of detecting high glucose (HG) and/or Diabetes mellitus (DM)-induced EPD irrespective of source or site. To remedy this lacuna we compared the test systems from both cell sources. Comparison of sensitivity of various cellular assays revealed that of all the assays performed, only colony formation assays (CFU) showed comparable responses to diabetes/high glucose in both test systems, while cell adhesion assay (CAA), proliferation potential and viability differed in their responses to HG. On the other hand, the functional assays i.e. tubule formation, chemotactic migration assay and CXCR4 and VEGFR2 mRNA expression were uniformly affected by HG in vitro and DM in vivo. Interestingly, other parameters studied i.e. nitric oxide, reactive oxygen species (ROS) and manganese superoxide dismutase (MnSOD) showed dissimilar responses to HG and DM exposure. On this basis, we propose a panel of assays comprising CFU, tubule formation, chemotactic-migration and CXCR4 and VEGFR2 mRNA expression that can accurately detect HG-/DM-induced EPD irrespective of various systemic factors. These assays will also enhance uniformity across data sets and increase accuracy of EPD detection in human and murine systems.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2203    
    Printed248    
    Emailed0    
    PDF Downloaded383    
    Comments [Add]    
    Cited by others 2    

Recommend this journal